The Suburban SW6D is a reliable direct vent gas water heater designed for recreational vehicles and mobile homes‚ offering efficient performance and fast recovery times․
1․1․ Overview of the Suburban SW6D Model
The Suburban SW6D is a direct vent gas water heater designed for recreational vehicles and mobile housing․ It features a 6-gallon capacity and delivers 12‚000 BTUh of power‚ ensuring efficient hot water supply․ With its compact design and lightweight construction‚ it is ideal for space-constrained applications․ The unit utilizes direct spark ignition for reliable operation and includes a modular board for advanced control․ Known for its fast recovery time and reduced cool water cycles‚ the SW6D is a popular choice for RV owners seeking consistent performance․
1․2․ Key Features and Benefits
The Suburban SW6D offers a 6-gallon capacity and 12‚000 BTUh of heating power‚ ensuring a steady supply of hot water․ Its direct vent design enhances safety and efficiency by venting combustion gases directly outside․ The direct spark ignition provides reliable lighting‚ while the fast recovery time minimizes cool water cycles․ Designed for RVs and mobile homes‚ it features a compact‚ space-saving design and lightweight construction․ The modular board allows for easy installation and maintenance․ These features make the SW6D a practical and efficient choice for on-the-go hot water needs․
Installation Requirements
The Suburban SW6D requires proper ventilation and must be installed in accordance with the manual’s guidelines․ Ensure correct placement and follow all safety precautions for direct vent gas systems․
2․1․ Pre-Installation Checks
Before installing the Suburban SW6D‚ verify the model matches your needs and ensure all components are included․ Check for any damage during shipping․ Ensure the installation site meets ventilation requirements and is clear of flammable materials․ Properly align the water heater to avoid obstructing vents or doors․ Verify the module board is securely mounted‚ as it is not pre-attached․ Ensure compliance with local codes and manufacturer guidelines for safe installation․ Always follow the manual’s instructions to avoid safety hazards․
2․2․ Step-by-Step Installation Process
Begin by attaching the door to the frame and securing it with the latch system․ Install chocks on both sides of the water heater as shown in the manual․ Mount the module board permanently‚ ensuring it is not left loose․ Connect gas lines securely‚ following local codes‚ and test for leaks․ Ensure proper ventilation by installing vents according to the specified clearance requirements․ Connect water lines‚ taking care to avoid cross-connections․ Finally‚ ensure the unit is level and properly grounded before powering it on․ Always follow the manual’s detailed instructions․
2․3․ Venting and Clearance Requirements
Proper venting is essential for safe operation․ Use only approved venting materials rated for high temperatures․ Ensure horizontal or vertical venting systems are installed according to local codes and manufacturer guidelines․ Maintain minimum clearances of 12 inches from combustible materials․ The water heater must not be installed in areas with limited ventilation or where flammable vapors are present․ Always follow the manual’s venting specifications to ensure compliance and safety․ Proper clearance and venting prevent carbon monoxide buildup and reduce fire hazards․ Adhere strictly to these guidelines for optimal performance and safety․
Operating the Suburban SW6D
The Suburban SW6D offers efficient operation with a fast recovery time and consistent water temperature․ Its direct spark ignition ensures reliable performance‚ while the thermostat provides precise control․
3․1․ Initial Start-Up and Testing
Before starting the Suburban SW6D‚ ensure all connections are secure and the unit is properly installed․ Turn on the water supply and check for leaks․ Set the thermostat to the desired temperature․ Press the reset button to initiate the ignition․ Monitor the burner to confirm it lights and operates smoothly․ Allow the heater to run for a few minutes to ensure consistent operation․ Test the water temperature to verify it reaches the set level․ If issues arise‚ refer to the manual or contact support․
3․2․ Daily Operation and Settings
The Suburban SW6D operates efficiently with a simple control system․ To begin‚ set the thermostat to your desired temperature using the knob located on the front panel․ Ensure the water supply is turned on and the gas supply is enabled․ Monitor the temperature gauge to confirm the water reaches the set level․ For energy savings‚ adjust the thermostat to a lower setting when not in use․ Regularly check the burner operation and ensure no unusual odors or noises are present․ Always follow the manual’s guidelines for optimal performance․
3․3․ Temperature Adjustment and Safety
The Suburban SW6D allows for precise temperature control‚ with settings ranging from 120°F to 140°F․ Adjust the thermostat knob on the front panel to achieve your desired temperature․ For safety‚ never exceed 140°F to avoid scalding risks․ A high-limit switch automatically shuts off the heater if it overheats․ Always ensure proper ventilation and monitor the temperature gauge․ If issues arise‚ the manual reset feature can be activated to restore operation․ Regularly inspect the thermostat and safety mechanisms to maintain optimal performance and prevent potential hazards․
Maintenance and Troubleshooting
Regular maintenance ensures optimal performance․ Inspect for leaks‚ clean burners‚ and check venting․ Address issues promptly‚ such as faulty thermostats or ignition problems‚ to prevent shutdowns․
4․1․ Routine Maintenance Checks
Regular maintenance is essential to ensure the Suburban SW6D water heater operates efficiently and safely․ Check for leaks around connections‚ clean the burner assembly‚ and ensure proper venting․ Inspect the pressure relief valve and anode rod for corrosion․ Verify that all electrical connections are secure and functioning correctly․ Suburban recommends checking the grommet-to-reset system and ensuring the module board is properly mounted․ Avoid installing a check valve directly at the inlet to prevent pressure relief valve weeping․ Regular inspections help maintain performance and extend the heater’s lifespan․
4․2․ Common Issues and Solutions
Common issues with the Suburban SW6D include no hot water‚ error codes‚ or ignition failures․ Check the gas supply‚ ensure proper ventilation‚ and verify electrical connections․ If the thermostat trips‚ reset it as instructed․ For persistent issues‚ refer to the troubleshooting guide in the manual․ Avoid installing a check valve directly at the inlet‚ as it may cause pressure relief valve weeping․ Regularly inspect and clean the burner assembly to prevent blockages․ Addressing these issues promptly ensures optimal performance and extends the heater’s lifespan․
4․3․ Parts Replacement and Upgrades
Replacing parts on the Suburban SW6D requires genuine components to maintain safety and efficiency․ The module board‚ thermostat‚ and burner assembly are commonly upgraded or replaced․ Ensure the module board is securely mounted‚ as it is not pre-attached․ When upgrading‚ follow the manual’s instructions for compatibility and installation․ Avoid installing a check valve directly at the inlet‚ as it may cause pressure relief valve issues․ Always test the system after replacements to ensure proper function and safety․ Regular upgrades can enhance performance and extend the heater’s lifespan․
Safety Precautions and Warnings
Always follow the Suburban SW6D manual for installation and operation․ Ensure proper ventilation to avoid carbon monoxide risks․ Never expose the heater to flammable vapors or materials․
5․1․ General Safety Guidelines
Always adhere to safety guidelines when operating the Suburban SW6D․ Ensure proper ventilation to prevent carbon monoxide risks․ Never install near flammable materials or in confined spaces․ Regularly inspect the unit for damage or leaks․ Only qualified technicians should perform repairs or adjustments․ Follow all local codes and regulations․ Keep the area around the heater clear of obstructions․ Properly secure the unit to prevent movement during vehicle transit․ Refer to the manual for specific warnings and precautions to ensure safe operation․
5․2․ Handling Gas and Electrical Components
When handling gas and electrical components of the Suburban SW6D‚ ensure all connections are secure and leak-free․ Never install a check valve directly at the water heater inlet to avoid pressure relief valve weeping․ Use only approved materials for gas lines and ensure proper ventilation․ Electrical connections must meet local codes and regulations․ Avoid overloading circuits or using damaged wiring․ Always follow the manual for specific instructions on gas and electrical system installation․ Ensure all components are installed by a qualified technician to prevent hazards․
5․3․ Emergency Shutdown Procedures
In case of an emergency‚ immediately turn off the gas supply to the Suburban SW6D water heater․ Switch the unit to the off position and disconnect the electrical power supply․ Ensure the area is well-ventilated to prevent gas accumulation․ If a gas leak is suspected‚ do not operate any electrical devices nearby․ Contact a qualified technician to diagnose and resolve the issue․ Always follow the manual for specific shutdown instructions to ensure safety and prevent potential hazards․
Technical Specifications
The Suburban SW6D is a direct vent gas water heater with a 6-gallon capacity‚ delivering 12‚000 BTUh․ It is designed for recreational vehicles and mobile housing‚ ensuring efficient performance and reliability in various conditions․
6․1․ Dimensions and Weight
The Suburban SW6D water heater measures 22․25 inches in height‚ 19․5 inches in width‚ and 9․5 inches in depth‚ making it compact for installation in RVs and mobile homes․ It weighs approximately 84 pounds‚ ensuring stability and ease of handling during setup․ These dimensions allow for efficient placement in tight spaces while maintaining accessibility for maintenance and repairs․ The unit’s lightweight yet durable design ensures it meets the demands of mobile living without compromising performance or safety․
6․2․ Performance Ratings and Capacities
The Suburban SW6D water heater delivers a 12‚000 BTUh input rating‚ ensuring efficient heating for consistent hot water supply․ Its 6-gallon capacity is optimized for recreational vehicles and mobile homes‚ providing ample water for daily needs․ The unit offers a fast recovery rate‚ minimizing cool water cycles and enhancing user convenience․ Designed for reliability‚ the SW6D maintains steady performance under varying conditions‚ making it a dependable choice for mobile living․ Its compact design and robust construction ensure long-lasting efficiency and reliability․
6․3․ Compliance and Certifications
The Suburban SW6D water heater is certified for installation in recreational vehicles and mobile housing‚ ensuring adherence to industry safety and performance standards․ It meets all applicable regulations for gas-fired water heaters in mobile applications․ The unit is listed by Airxcel‚ Inc․‚ and complies with the requirements outlined in the warranty and rating plate․ This certification guarantees that the SW6D operates safely and efficiently‚ providing reliable hot water solutions for mobile living․ Proper installation must follow the manual to maintain compliance and warranty validity․
Warranty and Customer Support
The Suburban SW6D water heater is backed by a comprehensive warranty‚ ensuring protection for parts and labor under specified conditions․ For assistance‚ contact Airxcel‚ Inc․‚ at 423-775-2131․ Proper installation maintains warranty validity․
7․1․ Warranty Terms and Conditions
The Suburban SW6D water heater is covered by a limited warranty provided by Airxcel‚ Inc․‚ ensuring protection for parts and labor under specific conditions․ The warranty period varies depending on the component‚ with detailed terms outlined in the product’s rating plate․ Proper installation‚ adherence to maintenance guidelines‚ and compliance with operational instructions are essential to maintain warranty validity; For inquiries or claims‚ customers can contact Airxcel‚ Inc․‚ at 423-775-2131․ The warranty does not cover damages resulting from improper installation or misuse․
7․2․ Contacting Customer Service
For assistance with the Suburban SW6D‚ customers can contact Airxcel‚ Inc․‚ at 423-775-2131․ The company is located at 676 Broadway Street‚ Dayton‚ Tennessee‚ 37321․ Representatives are available to address inquiries‚ provide support‚ and assist with warranty-related matters․ Customers are encouraged to have their model number and serial number ready for efficient service․ Airxcel‚ Inc․‚ is committed to ensuring customer satisfaction and resolving issues promptly․